Studies on Variations in Haematobiochemical Profile of Dogs Treated with Titanium Elastic Stable Intramedullary Nailing for Long Bone Fractures
DOI:
https://doi.org/10.5455/ijlr.2021101Keywords:
Dogs, ESIN (Elastic Stable Intramedullary Nailing), TitaniumAbstract
The study was conducted on ten dogs presented with diaphyseal fracture of long bones. All the fractures were repaired by titanium elastic stable intramedullary nailing. To study the haemato-biochemical profile of the dogs blood samples were collected in EDTA and serum collecting vials at different time intervals i.e., pre-operative, immediate post-operative, on 15th, 30th and 60th post-operative days. There were statistically significant variations in the mean values of total leucocyte count, neutrophils (%), lymphocytes (%), platelet count, serum calcium and sodium ion levels during the different time intervals of observation. But clinically, all the haematological and serum biochemical parameters were within the normal range for dogs. So it was inferred that application of titanium elastic stable intramedullary nailing does not cause any systemic adverse effects in dogs.References
Aron, D.N. (1998). Practical techniques for fractures. In: Bojrab M.J. ed. Current techniques in small animal surgery. 4th ed. Philadelphia, Williams & Wilkins. pp. 934-941.
Hansda, P., Gahlod, B.M., Akhare, S.B., Dhakate, M.S., Upadhye, S.V. and Panchbhai, V.S. (2012). Comparative evaluation of Steinmann pin, Kuntscher nail and interlocking nail for femur fracture repair in dog. Indian Journal of Veterinary Surgery. 33(1): 53-54.
Harasen, G. (2001). Fractures involving the distal extremity of the femur. Part 1–The immature patient. The Canadian Veterinary Journal, 42(12): 949–950.
Komnenou, A., Karayannopoulou, M., Polizopoulou, Z.S., Constantinidis, T.C. and Dessiris, A. (2005). Correlation of serum alkaline phosphatase activity with the healing process of long bone fractures in dogs. Veterinary Clinical Pathology, 34(1): 35–38.
Lascombes, P., Haumont, T. and Journeau, P. (2006). Use and abuse of flexible intramedullary nailing in children and adolescents. Journal of Pediatric Orthopedics, 26(6): 827–834.
Maiti, B.K., Sen, T.B., Singh, B. and Sanki, S. (1999). Haematobiochemical changes following application of internal fixation technique in treatment of femur fracture in dog. Indian Journal of Animal Health, 38: 133-134.
Niinomi M. (2001). Ti based biomaterials, the ultimate choice for orthopaedic implants- A review. Metallurgical and Materials Transactions, 32(1): 477–486.
Schwarz, P.D. (1991). Biomechanics of fractures and fracture fixation. Seminars in Veterinary Medicine and Surgery (Small Animal), 6(1): 3–15.
Shahar, R. (2000). Relative stiffness and stress of type I and type II external fixators: acrylic versus stainless-steel connecting bars--a theoretical approach. Veterinary Surgery, 29(1): 59–69.
Downloads
Published
How to Cite
Issue
Section
License
This work is licensed under a Creative Commons Attribution 4.0 International License.